Listing 3. Rotating System Input to SCEPTRE

CIRCUIT DESCRIPTION
DEFINED PARAMETERS
DPX1 = X1 (-100.*PX1-1000.*PX3+1.E4)
DPX2 = X2 (-100.*PX2+1000.*PX3)
DPX3 = X3 (10.*PX1-10.*PX2)
PX1  = 0
PX2  = 0
PX3  = 0
PERAB3 = X13 (PX3-VC1)
ELEMENTS
E1,   5-1  =  10
C1,   3-5  =  0.1
R1,   2-3  =  0.1
R2,   4-5  =  0.1
L1,   1-2  =  1E-3
L2,   3-4  =  1E-3
OUTPUTS
PX1(W1), PX2(W2), PX3(TS), IR1(I1)
IR2(I2), VC1(VC), PERAB3
RUN CONTROLS
STOP TIME = .099